I think I have found my answer – as this switch is not participating in spanning tree – I believe that :
STP configured to ON, priority is level0 Is forwarding the BPDU’s unmodified. Would I be correct in this assumption? I see the correct Bridge ID’s as if this switch is not there. From: Nick Cutting Sent: Tuesday, May 17, 2016 3:26 PM To: Nick Cutting; Eldon Koyle Cc: [email protected] Subject: RE: [f-nsp] Spanning tree on brocade Now I have another switch – that has no IEEE spanning tree, No 802w, and no pvst configured. however, it says it is enabled on the port?? 10GigabitEthernet23 is up, line protocol is up Hardware is 10GigabitEthernet, address is 748e.f821.57d3 (bia 748e.f821.57e9) Configured speed 10Gbit, actual 10Gbit, configured duplex fdx, actual fdx Member of L2 VLAN ID 501, port is untagged, port state is FORWARDING BPDU guard is Disabled, ROOT protect is Disabled Link Error Dampening is Disabled STP configured to ON, priority is level0 Now – the loops prevention is on the otherside – and they are receiving BPDU’s on this switch – how can this be possible with no stp config? Can someone please elaborate on the port level spanning tree? Thanks !
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp