I would just do
mri_vol2vol --i vin.nii --regheader --targ orig.mgz --o vout.mgz


On 10/22/2018 05:52 PM, GREGORY R KIRK wrote:
>
>         External Email - Use Caution
>
> thanks Doug, one more thing to make sure I get it correct.
>
>
> If I have a volume of quantitative MR volumes in the native space of 
> the T1 and I want them to be in registration with the freesurfer space
>
> of this subject I woiuld
>
>
> mri_convert -it nii -ot mgz vin.nii vout.mgz and then
>
> mri_convert vout.mgz vc.mgz --conform --no_scale --nochange
>
>
> so that it is in the freesurfer space but not scaled and not changed 
> from float to uchar, correct ?
>
>
> thanks
>
>
> greg
>
> ------------------------------------------------------------------------
> *From:* freesurfer-boun...@nmr.mgh.harvard.edu 
> <freesurfer-boun...@nmr.mgh.harvard.edu> on behalf of Greve, Douglas 
> N.,Ph.D. <dgr...@mgh.harvard.edu>
> *Sent:* Monday, October 22, 2018 11:58:51 AM
> *To:* freesurfer@nmr.mgh.harvard.edu
> *Subject:* Re: [Freesurfer] resampling data onto cortical surface
> Use --s subject instead of --reg (run mri_vol2vol with --help to get
> more info).
> btw, if you have multi echo data, you are probably measuring R2*, not R1.
>
> On 10/22/2018 12:55 PM, GREGORY R KIRK wrote:
> >
> >         External Email - Use Caution
> >
> >
> > I have R1 values that I want to resample onto the cortical surface.
> > The R1 values were computed from a multi echo
> >
> > T1 sequence that was also used to create the T1 weighted image that
> > was used in recon-all to produce the cortical surface reconstructions
> >
> > and thus is inherently in registration to the 001.mgz that was used to
> > start recon. There will be a difference in orientation in the volume
> >
> > in that orig.mgz is in coronal and in the .mgz format.
> >
> >
> > I was thinking that if I run the first step of recon-all it should
> > give me an volume named orig.mgz that is in registration to the
> > freesurfer space
> >
> > for the subject ... or else some call to mri_convert reslice_as or
> > whatever is used in the recon-all script to convert 001.mgz to orig.mgz
> >
> >
> >
> >
> > then my problem is to get a file with the resampling of the R1 onto
> > the cortical surface withR1 values at each vertex.
> >
> >
> > when i work with fmri data I run bbregister and get the transformation
> > from the epi volume to the freesurfer space and then use
> >
> > mri_vol2surf --mov sig.nii \to resample the data onto the cortical 
> surface
> >      --reg bb.register.dat \
> >      --projfrac 0.5 --interp nearest \
> >      --hemi lh --o lh.sig.mgh
> >
> > to resample the epi data onto the cortical surface. however in this 
> case the R1 data
> > is already in perfect registration to the T1 other than the 
> reorientation and reslicing
> > done to prepare the orig.mgz volume.
> >
> > so can someone tell me what is the proper way to cook this goose
> >
> > Greg
> >
> >
> >
> > _______________________________________________
> > Freesurfer mailing list
> > Freesurfer@nmr.mgh.harvard.edu
> > https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to