Bonjour,
Voila ce que ca donne avec une sup720-3bxl + 2xX6704-10G + X6724-SFP qui
fait du 736Kpps au moment du dump:
---------------------------------------------------------
/border-gateway#sh power
system power redundancy mode = redundant
system power total = 1869.42 Watts (44.51 Amps @ 42V)
system power used = 1257.48 Watts (29.94 Amps @ 42V)
system power available = 611.94 Watts (14.57 Amps @ 42V)
Power-Capacity PS-Fan Output Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------ ------ -----
1 PWR-1900-AC/6 1869.42 44.51 OK OK on
2 PWR-1900-AC/6 1869.42 44.51 OK OK on
Pwr-Allocated Oper
Fan Type Watts A @42V State
---- ------------------ ------- ------ -----
1 FAN-MOD-6HS 180.18 4.29 OK
Pwr-Requested Pwr-Allocated Admin Oper
Slot Card-Type Watts A @42V Watts A @42V State State
---- ------------------ ------- ------ ------- ------ ----- -----
1 WS-X6724-SFP 125.16 2.98 125.16 2.98 on on
4 WS-X6704-10GE 295.26 7.03 295.26 7.03 on on
5 WS-SUP720-3BXL 328.44 7.82 328.44 7.82 on on
6 WS-X6704-10GE 328.44 7.82 328.44 7.82 on on
/---------------------------------------------------------
Salim
Le 18/07/2012 16:37, Alexandre Legrix a écrit :
> Bonjour.
>
> Nous cherchons à savoir, si il existe un tableau comparatif des consommations
> électrique de différents matériel Cisco afin de bâtir un modèle économique
> long terme.
> Je ne trouve pas ce type d'information.
> Je cherche à savoir par exemple combien consomme pour de vrai un :
> 6503-E + sup32 + 6724
> ou un 3750G-12s
>
> A pleine charge avec tous les ports qui poussent du trafic, ou pas … etc ...
>
> Si quelqu'un sait ou je peux chopper l'info, je lui serai reconnaissant.
>
> Alexandre Legrix.
>
>
> ---------------------------
> Liste de diffusion du FRnOG
> http://www.frnog.org/
--
Salim Gasmi -- Directeur Technique -- SdV Plurimedia
---------------------------
Liste de diffusion du FRnOG
http://www.frnog.org/