https://gcc.gnu.org/g:aa4345370bf4fb1077b1559c0f8a17e6b90b2b41
commit r17-4434-gaa4345370bf4fb1077b1559c0f8a17e6b90b2b41 Author: Xavier Del Campo Romero <[email protected]> Date: Thu Sep 17 23:18:55 2026 +0200 cobol: Set loc also for numeric literals BY REFERENCE Otherwise, diagnostics could be printed with invalid or missing location data. For example, location data is missing from the following diagnostic: argloc.cbl: error: parameter 2 BY REFERENCE ‘0’ (NUMERIC LITERAL, capacity 1, unsigned) invalid for ‘foo’ parameter BY REFERENCE ‘param-b’ (COMPUTATIONAL-5, capacity 4, signed) gcc/cobol/ChangeLog: * parse.y: Set loc also for numeric literals BY REFERENCE. Diff: --- gcc/cobol/parse.y | 1 + 1 file changed, 1 insertion(+) diff --git a/gcc/cobol/parse.y b/gcc/cobol/parse.y index 1e0bbbcb663d..0552f77f6193 100644 --- a/gcc/cobol/parse.y +++ b/gcc/cobol/parse.y @@ -10914,6 +10914,7 @@ ffi_by_ref: scalar_arg[refer] "cannot pass %qs BY REFERENCE", $1->data.original()); cbl_refer_t *r = new_reference($1); + r->loc = @1; $$ = new cbl_ffi_arg_t(by_content_e, r); } | ADDRESS OF scalar_arg[refer]