Hi Duncan, I'm the one who wrote the DRC checker... El jue, 13-09-2007 a las 20:58 +0200, Duncan Drennan escribió: > > The NC symbol has device=DRC_Directive, and value=NoConnection. > > Back to the topic: is there a way to modify the scheme so that the > netlister will skip DRC_Directive devices when assigning net names?
If you connect the NC symbol to any net which has only one connection, the DRC should not report any warnings or errors. If you get warnings or errors, it's a bug. There is a test case schematic in gaf sources just to check this. It's at: gnetlist/tests/drc/unconnected-pin-with-drc-directive.sch Can you please run the DRC with that schematic and verify that no warnings neither errors are issued?. The correct result is stored at: gnetlist/tests/drc/unconnected-pin-with-drc-directive.drc2 If this test run ok for you, please submit a small schematic showing the error, and I'll try to track it down. Thanks, Carlos _______________________________________________ geda-user mailing list [email protected] http://www.seul.org/cgi-bin/mailman/listinfo/geda-user