Hi, We run tests which use atomic operations (both fetch and add and comp and swap) on PPC64 all the time, without experiencing any problem.
Just to make sure I ran few simple tests, which use atomic operations, on our PPC64 machines, both with SLES10 SP1 and with RHAS5.1, and all of them passed. I was working with the latest OFED1.4 driver and mlx4 HCA with the latest released FW and with FW 2.3.000 (on the SLES10 SP1 machine). Given the above information I believe that there's either a problem with your code (although looking at the code you posted I couldn’t see anything wrong) or it's an OFED1.2.5 issue, as Dotan suggested. Ronni. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Rui Machado Sent: ו 19 ספטמבר 2008 17:39 To: Dotan Barak Cc: [email protected] Subject: Re: [ofa-general] atomic operations on ppc64 2008/9/19 Dotan Barak <[EMAIL PROTECTED]>: > >>> It seems that you didn't check the same HCA in each arch. >>> >>> Can you try to use the mthca device in PPC64 and check the results? >>> >>> (Anyway, i would have suggest you to upgrade the OFED package that >>> you are >>> using) >>> >> >> I apologize for my newbieness here but I do not understand what you mean. >> The two machines have different devices. What do you mean by making >> the ppc64 machine use the mthca when it does only have the mlx4? >> >> Unfortunately, upgrading might not be an (easy) option :-/ >> >> Thanks for the patience >> > > You have 2 machines, each with another device: > x86 has the HCA 25204 > PPC64 has the HCA 25418 > > > The fact that the test didn't pass for you on the PPC64 may be related > to this device (i think that OFED 1.2.5 was the first version that > supported this device). > > So, i suggest that you'll put the HCA 25204 on the PPC64 and check if > the failure still exists. > > > Dotan > Right :) Now I get it! I couldn't (yet at least) put the HCA 25204 on the ppc64. But I tried again with another ppc64 machine. ibv_devinfo hca_id: mthca0 fw_ver: 4.8.200 node_guid: 0005:ad00:001d:cd24 sys_image_guid: 0005:ad00:0100:d050 vendor_id: 0x05ad vendor_part_id: 25208 hw_ver: 0xA0 board_id: HCA.HSDC.A0 phys_port_cnt: 2 port: 1 state: PORT_ACTIVE (4) max_mtu: 2048 (4) active_mtu: 2048 (4) sm_lid: 142 port_lid: 156 port_lmc: 0x01 port: 2 state: PORT_DOWN (1) max_mtu: 2048 (4) active_mtu: 512 (2) sm_lid: 0 port_lid: 0 port_lmc: 0x00 The result was still the same as before: ppc64-ppc64 - the counter doesn't get updated. ppc64-x86 - clients hangs at poll Just as an extra info... _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general _______________________________________________ general mailing list [email protected] http://lists.openfabrics.org/cgi-bin/mailman/listinfo/general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general