Hi GMX community,
We're doing some MD involving Xenon atoms. For our parameterization, we
obtained sigma and epsilon (over kB) values of 3.975 Ang. and 214.7 K,
from the following JCP reference:
http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JCPSA6000120000014006674000001&idtype=cvips&gifs=yes
We then calculated the C6 and C12 nonbonded parameters for a Xe Xe
interaction, based on combination rule #1, as specified on page 88 of
the GMX manual. We obtained: C6 = 0.0282 and C12 = 1.11e-4
Does this look reasonable? Are there others out there that have done
Xenon MD, willing to share their nonparm. numbers?
Thanks,
Arneh
_______________________________________________
gmx-users mailing list [email protected]
http://www.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at http://www.gromacs.org/search before posting!