Hey, Wikipedia has some info for you but not much. The smaller stuff is easier to get information for however.
In the US now. Most wall outlets are rated at 20A 120V or 24KW. That works out to be about 1 FT/14 seconds. Most smaller houses (and many older larger ones) the breaker box is rated at 100A 120V or 120KW. That would be about 1 FT/ 3 seconds. A small substation typically has 5000 KVA (effectively 5MW) which would give 1.4 FT/sec but would cause a large enough disturbance that the power company would probably cut it off in a few minutes. A large substation (typical in European urban areas) would be around 20MW and would give around 6FT/sec. Using this as a power source would definitely attract the attention of the power company and they would likely do something about in short order. Anything larger than this gets more difficult to find data for and is much more likely to enact responses designed to prevent region wide black outs with no more than a few seconds of full access to available power. A lead acid car battery has around a 30WH/kg energy density. So a 5kg battery would have about 1.5 FT in it. A modern A2 Humvee with a 6.5L V8 Diesel engine with 160 horse power which equates to about 1FT/3 seconds. >From the Grimoire errata page I get this handy dandy little table. I assume it is pretty close to the 4E version - just watch the TL differences between editions. http://www.sjgames.com/errata/gurps/grimoire.html Revised Power Equivalents A Cell (TL 8) 0.1 fatigue B Cell (TL 8) 1 fatigue C Cell (TL 8) 10 fatigue D Cell (TL 8) 100 fatigue E Cell (TL 8) 1000 fatigue 1 MWH 10000 fatigue 1 KWH 10 fatigue 3400 btu 10 fatigue 360 KW 1 fatigue/second 18 MW 50 fatigue/second 965 Horsepower 2 fatigue/second Power cells hold 50% more energy per TL beyond 8. All power cells in the examples are assumed to be TL 8. I hope this info helps out. I would think the energy available at higher tech levels would go up at the +50%/TL as well. So infinities TL9 power grid on a world with mana (ie not Homeline) would probably be able to give a player the ability to draw 2FT from a substation or 9FT per second from a big one if they didn't mind blacking the neighborhood out and getting cut off in short order. Others with better access to resources will probably be able to find you some more information, and be able to check mine. Clint "Holmes, Erik" <[EMAIL PROTECTED]> Sent by: [EMAIL PROTECTED] 06/26/2006 02:13 PM Please respond to The GURPSnet mailing list <[email protected]> To To "The GURPSnet mailing list" <[email protected]> cc Subject RE: [gurps] Power Sources for Draw Power Caterpillar: Confidential Green Retain Until: 07/26/2006 Retention Category: G90 - General Matters/Administration > I know it's going to come up but so far I can't find any easy > examples of which types of power sources offer what kind of power. > > The character is question has 10 levels of Magery. What I am > looking for is a good list or maybe just a good explanation > of what kind of power he could draw from things like car > batteries, power lines, etc. How would these change with TL? Anyone have any good resources for looking this stuff up? I haven't had much luck finding out the output of powerlines, etc. :( > Most of the worlds that the characters will travel to will be > about 8-9, with maybe some TL 10. What kind of power sources > can I expect the character to tap into in worlds like those? > I'm mainly concerned with portable power sources or common > power sources. Will the character just be able to carry > around a few thousand energy in a backpack or something? What I meant here is would a TL 9 Power Line put out more KW then a TL 8 powerline? _______________________________________________ GurpsNet-L mailing list <[email protected]> http://mail.sjgames.com/mailman/listinfo/gurpsnet-l _______________________________________________ GurpsNet-L mailing list <[email protected]> http://mail.sjgames.com/mailman/listinfo/gurpsnet-l