Hello Ottar, I think you maybe had got PATH errors when you configured CHPID B8 online.
Please supply messages resulting from the CF CHP(B8),ONLINE command, including any path related messages. Also please provide complete D M=CHP(B0,B8) report. The additional data might provide the missing clue. On Mon, 30 May 2005 10:43:22 -0500, Ottar Moller <[EMAIL PROTECTED]> wrote: >Hi there, >I was adding a new CHP to a device and reused an old CHP. I can't get the >new CHP working and when I list the CHP (d m=chp(B8)) I get: > >CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE > >When looking at the other CHPs for the same device I get: > >CHPID B0: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE > >They are both defined as CNC and I can't find out where to change TYPE=04 to >TYPE=03. > >Any hints? > >Best regards, > >Ottar > Regards Bruce Hewson ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html