On Sat, 19 Jun 2010 04:07:23 -0500, Thierry Deleris
<[email protected]> wrote:

>Hello,
>
>First a big thank to Jan, Ravi and Tom for their lights on this subject !
>
>I will try to make a diagram of the different times involved in the SMF30
>records before initiation time to complete my analyses thanks to your
>informations.
>
>Another question about these following lines from Tom response :
>
>"11.08.15 JOB94550 ---- TUESDAY,   01 JUN 2010 ----
>This is when the first message is placed in the job log for the job.  This
>is when the data set is created.  In general, the first message for a job is
>the RACF message that the job has been authenticated and assigned a userid.
> This occurs at the end of input processing (when JES2 realizes that it has
>a complete job)."
>
>==> Is there a SMF Data zone where we could find the "End of input
>processing time" or the "Input processing times for the job" ?
>
>And finally :
>
>==> Why in some cases could we see some "Waiting Time for init (SMF30SQT)" >
>"Time between Reader time (SMF30RST) and Start time (SMF30SIT)" ?
>
>Best regards,
>
>Thierry Déléris


Suggest you also look at the SMF type 26 data source as well as the SMF 30.

Scott Barry
SBBWorks, Inc.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to