On Thu, 30 Sep 2010 13:50:37 +0000, Rob Scott <[email protected]> wrote:

>John,
>
>>> Why can't SMP/E do the ICKDSF PUTIPL command as well? It should know the
volser to update - it is the one containing the updated SYS1.NUCLEUS.
>
>Surely most sites do not IPL their system from the SMP/E volumes and
datasets - there is normally some sort of propagation JCL to copy to "real"
runtime SYSRES volumes - and as stated previously there is no harm to suffix
that copy JCL with a PUTIPL.
>

Many do - at least in a sandbox (I have been at shops in the past that have
done it that way... especially before DASD was "cheap").  

I haven't been in a shop that did it that way in quite a while, but my current
shop (and most others I've been at) do clone via full volume copy of their
maintenance volume, so that is essentially the same thing.

However...

Some of the shops I've been at clone via logical copy instead of full volume
copy of their IBM maintenance sysres, in that case, doing the task within
SMP/E wouldn't do anything put create a WTOR for someone to respond
to.  Of course those cloning procedures included a step to create IPLTEXT
every time you cloned, so it wouldn't have been an issue regardless.

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS       
mailto:[email protected]                                          
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html 
Systems Programming expert at http://expertanswercenter.techtarget.com/

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to