John,
You do not explain what procedure you used exactly. In order to be able to
replace SMF exits such as IEFACTRT, the exits have to have been loaded
dynamically to begin with. You would do this with the PROGxx PARMLIB member.
Liliane
At 03:33 PM 11/21/2005, John Norgauer wrote:
We recently attempted to replace our IEFACTRT routine in our production
platform using TMON..
Well, as luck would have it, our system appeared to freeze up. We had been
able to do this replace function
successfully on our test LPAR.
Anyone care to comment on this type of a replacement in dynamic LPA...
hazards, potential problems?
Thanks
John Norgauer
University of California Davis Medical Center
2315 Stockton Blvd
ASB 1300
Sacramento, Ca 95817
916-734-0536
SYSTEMS PROGRAMMING...... Guilty, until proven innocent !! " JN 2004
........