Try RECYCLE ALL PERCENTVALID(100) EXECUTE

After removing the 3490E as valid target volumes.  


Dave Gibney                              [EMAIL PROTECTED]
System Programmer                        (509) 335-7359
Information Technology
Washington State University
Pullman, WA 99164-1222

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
> Behalf Of McKown, John
> Sent: Thursday, February 09, 2006 11:56 AM
> To: [email protected]
> Subject: DFHSM tape recycle question.
> 
> We are planning on moving our DFHSM ML2 volumes from our manual 3490E
> tapes to a virtual library (3494-B10). The simpliest way that I can
> think of is to do this is to just issue HSEND RECYCLE VOLUME(......)
> EXECUTE commands. Unfortunately, these seem to single thread. Somebody
> here said that multiple concurrent recycles could be done if multiple
> RACF ids issued the HSEND commands. Is there some way to have a single
> batch job (or series of batch jobs actually) issue RECYCLE commands
and
> have those commands run concurrently (up to MAXRECYCLETASKS)? Right
now,
> I have MAXRECYCLETASKS equal to 4.
> 
> Note - I know that we cannot use these ML2 tapes in a D.R. scenario.
We
> have a product which is supposed to "stack" multiple virtual 3490E
> volumes onto a single 3592J volume, then "unstack" at the disaster
site.
> It also issues some DFHSM commands (TAPEREPL) to then use the just
> created virtual 3490E tapes in DFHSM. At least, as I understand it.
This
> note is irrelevant to my actual question and is included only for
> informational purposes.
> 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to