> -----Original Message-----
> From: IBM Mainframe Discussion List 
> [mailto:[EMAIL PROTECTED] On Behalf Of Alan C. Field
> Sent: Monday, February 27, 2006 12:19 PM
> To: [email protected]
> Subject: Re: Changing an IODF in batch
> 
> 
> Could you PUNCH out your deck using the panels and save the output.
> 
> Then you can simply edit the PUNCH file to make the changes 
> and run the 
> batch program to migrate the deck back in?
> 
> Something like:
> 
> //MIGRATE  EXEC PGM=CBDMGHCP,REGION=256M, 
> //         PARM='MIGR,IP,SY1,2084-B16,LPAR' 
> //HCDIODFT DD   DISP=SHR,DSN=SYS1.IODF03.WORK 
> //HCDIN    DD   DISP=SHR,DSN=your punch file
> 
> Alan 
> 

Thanks, I'll give that a look!

--
John McKown
Senior Systems Programmer
UICI Insurance Center