Jorge, One last thought, have you asked on the CICS-L list. They may have some experience with this type of issue.
Lizette -----Original Message----- >From: [EMAIL PROTECTED] >Sent: Mar 24, 2006 6:15 PM >To: IBM Mainframe Discussion List <IBM-MAIN@BAMA.UA.EDU> >Subject: Re: CICS down after transaction exec wait macro. > >Jorge, > >I assume you are CICS TS2.2???? what version of operating system? > > >I am not sure but I think you need to start with a S0201 abend with MVS or >z/OS. In the MVS messages & codes (or z/OS) the error indicaties: > 201 > > Explanation: During processing of a WAIT macro, the system found either: > > O The macro expansion contained an incorrect address for an event > control block (ECB) > > O The program issuing the WAIT macro was not running under the same > storage protection key as the storage containing the ECB > > System Action: The system abnormally ends the program that issued the > WAIT macro. > > Programmer Response: Ensure that the ECB address specified is a valid > virtual storage address and that it was not incorrectly modified. Correct > the error. Run the job again. > > >Not sure if this helps. If I had a dump to look at, I could see if this >applies or not. If this is the case, then I would ask what has changed. Any >code changes, ptfs installed, the normal drill. > >Lizette Koehler ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html