Jerry,

Now would be a good time to move to response time goals for CICS (before the upgrade). In the mixed environment, the achieved velocities may vary widely, but the RT goals should be met on either platform.

Good luck!

Steve Samson

J Ellis wrote:
We are going to have a 2094-604- 4 engines at approx 435mips per engine and a 2064-2C9- 9 engines at approx 232mips per engine in our plex. Three lpars on the 2094 and two on the 2064. Workload is CICS/DB2/IMS/MQ with lots of DDF mixed in during the day as well as user critical batch that also runs during the online day, heavy batch at night. The concern is trying to adjust WLM for the different hardware, i.e. a velocity of 30 on the 2094 means something different than velocity 30 on the 2064 within the same plex, correct ? Has anyone had any experience with this type of configuration ?

----------------------------------------------------------------------