Thanks Bruce. I will try it out. Can the FDR group come up with another
section where the failed volume will be flagged? This way it could be easier
to zero in on the problem. Now, only a list of the successful volumes that
have been backed up appear on the list.
Willie, I am not quite sure what you are looking for. If "by the list"
you mean the output of the FDRSUMM DD statement, that list does show
successful and failed backups but it does not show volumes which were
bypassed like this one, since they don't proceed far enough in the
process to generate the summary line.
SYSPRINT will show the success or failure of each volume, although you
may need to examine the SYSPRINx outputs to find specific error messages
--
Bruce Black
Senior Software Developer
Innovation Data Processing
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html