That's what I was going to suggest, too.

TCBUSER did serve its purpose in the day, but I can remember a time a
conflict occurred in three different products that my then-employer sold.

When I had to add something similar to a product a few years, name/token was
(and is) the way to go.

Later,
Ray 

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf
Of Craddock, Chris
Sent: Friday August 25 2006 07:38
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: SVC Screening and TCBUSER

> My question is:
> Is it safe to pass the CPID from the main program to the Screen
routine
> through the TCBUSER ? Do I have a better alternative ?

Not a chance. You should use the name/token service. It does what you need
and its really fast.

----------------------------------------------------------------------