Mike,
I agree with Alan. Try to convert the VTOC from indexed to OS, and then
back again. Here are the statements I use in ICKDSF:
Convert to OS
BUILDIX -
DDNAME(DISK) -
OS NOPURGE
Convert back to Indexed
BUILDIX -
DDNAME(DISK) -
IX
Cliff McNeill
Mike,
I'd try disabling and then rebuilding the vtoc index before you go as far
as re initing.
Sounds like there is an entry in the index that isn't on the volume.
ICKDSF BUILDIX ...
Mike Szyszka <[EMAIL PROTECTED]>
Sent by: IBM Mainframe Discussion List <[email protected]>
09/22/2006 09:35
Please respond to
IBM Mainframe Discussion List <[email protected]>
To
[email protected]
cc
Subject
VTOC trashed?
Hi all,
ISPF Option 3.4 with just the volser, I receive message in the upper right
corner of the screen.
"Incomplete VTOC list"
PF1 shows
"Index entry not included because VTOC entry does not exist."
I assume this dasd is trashed and need to be re-inited?
The data sets are still working. I can allocate a new datasets.
One problem is that it is a system pack.
--
Thanks,
Mike
----------------------------------------------------------------------