On Sun, 24 Sep 2006 20:59:03 -0400, Bruce Black <[EMAIL PROTECTED]> 
wrote:

>>
>> And both names will
>> be ENQed, so the real point here is that your alias suggestion won't 
work.

>Mark, I think you are wrong.  

Bruce,

Test it.   Define an alias of A.B.C to data set A.B  Run a job with
DISP=OLD for data set A.B.C on system A.  On system B run a job with
DISP=SHR pointing to data set A.B.  I'm not a betting man, but I'm
pretty sure the job on system B will be waiting on a reserved name.
I haven't tested it yet either, but you can bet that I will in 
the morning.  :-)

Regards,

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group
mailto: [EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------