At 07:58 -0700 on 10/21/2006, Charles Mills wrote about Re: Is the teaching of non-reentrant HLASM coding practices:

And then there is no way to test that the code really is reentrant (that I
know of -- am I missing something?) without running it APF-authorized.

Use RENT as well as RSECT instead of CSECT and you will get TOLD at assembly time when you're not reentrant.

----------------------------------------------------------------------