Johnny
I have reviewed your files and tried to find something useful in the PCOMM
manual - also the so-called "Quick Beginnings".
I see no reference to APPC3270 in the .acg file. Maybe APPC3270 is tied to
using AnyNet SNA over IP in some way. If the only way to be able to enter
the "Attachment" type APPC3270 is with an AnyNet SNA over IP logical link,
you might try to define one and never activate it.
Regarding a detail in the .acg file, in general, you do not actually need to
define any local LUs since you necessarily define a CP and a CP can always
be used as a local LU.
Otherwise, the .acg file looks unexceptionable.
In a way, APPC3270 is unnecessary since DLUR/DLUS supports the same function
and is more "strategic". Thus it wouldn't surprise me that APPC3270 works
only in obsolete configurations.
Chris
----- Original Message -----
From: "Johnny Luo" <[EMAIL PROTECTED]>
Newsgroups: bit.listserv.ibm-main
To: <[email protected]>
Sent: Saturday, February 24, 2007 12:53 PM
Subject: Re: Do I need to setup APPC/MVS?
Chris,
I have sent you a mail offline including a document about my whole
configuration process.
I didn't find any IBM manuals about APPC3270 over EEDLC using PCOMM.
http://publib.boulder.ibm.com/infocenter/pcomhelp/v5r9/index.jsp
Here you can find the docs about IBM Personal Communications 5.9 but they
only talk about APPC3270 over ANYNET briefly.
Johnny
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html