Hello Patrick, I'm not sure about NIP consoles but if that NIP console address is defined in a CONSOLxx member, as someone else said you won't be able to activate. You will get the message that Hal listed below. If it is just a NIP cons and not in any CONSOLxx member, I don't know - but I'd like to, if someone knows.
I had the same problem a while back making multiple changes to an IODF. In my case I was changing some old consoles from static to dynamic so I could delete them in a future IODF. I had to delete my prod IODF, go back to my work iodf and remove the static to dynamic change before I could activate the rest of the changes I was making. I don't think ACTIVATE TEST catches the problem. I'm no expert... just passing on what I found out a while back... Robert -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Patrick Lyon Sent: Friday, April 20, 2007 10:45 AM To: [email protected] Subject: Re: Deleting console UCB's On Fri, 20 Apr 2007 01:27:18 -0500, Bruce Hewson <[EMAIL PROTECTED]> wrote: >Hello Hal, > >The device is/was defined as a NIP console. > >This is another reason I do NOT code any device as a NIP console. > >I seem to remember that I was able to UNPIN the device somehow. >Not sure how I did it, but I did have access to some UNPIN code from EMC >some years ago. > >On Thu, 19 Apr 2007 13:52:09 -0500, Hal Merritt <[EMAIL PROTECTED]> >wrote: > >>Here is the message. >> >>E IOS500I ACTIVATE RESULTS >> # ACTIVATE FAILED - ERROR MESSAGE(S) ISSUED >> _ E REASON=0151,CAN NOT DELETE DEVICE 0720 >> # DESCTEXT=DEVICE PINNED, ASID = 0001 >> # DEVICE IN USE AS A CONSOLE >> # COMPID=SC1CK >> >>The device is not only off line but does not physically exist. > > >Regards >Bruce Hewson > Bruce - Are you saying you cannot do a dynamic activate removing devices from NIPCON? If that is the case I will be attempting to do the very same thing this Sunday when I put in other hardware changes. Are you saying it will fail? When I do an ACTIVATE with the test option, it comes back with no reasons it would fail. Thanks for bringing this up. Confidentiality Notice: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html