In case others would have a similar interest, I did an experiment.
This is unsupported:

Case 1:
-------

PARMLIB  SYS1.PARMLIB.&SYSR1

At IPL we get:

IGGN307I sysr1,SYS1.PARMLIB.&SYSR1,DATA SET NOT FOUND ON VOLUME    
IEA345A SYS1.PARMLIB.&SYSR1 NOT USED (NOT CATALOGED) - PRESS ENTER TO
CONTINUE 

Case 2:
-------

Tried to cheat, defined ALIAS:

DEFINE ALIAS( NAME(SYS1.PARMLIB.SYSR1) -     
       SYMBOLICRELATE(SYS1.PARMLIB.&SYSR1))  

PARMLIB  SYS1.PARMLIB.SYSR1

At IPL we get:

IGGN307I sysr1,SYS1.PARMLIB.SYSR1,DATA SET NOT FOUND ON VOLUME    
IEA345A SYS1.PARMLIB.SYSR1 NOT USED (NOT CATALOGED) - PRESS ENTER TO
CONTINUE

Needless to say, I am disappointed...

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html