In case others would have a similar interest, I did an experiment.
This is unsupported:
Case 1:
-------
PARMLIB SYS1.PARMLIB.&SYSR1
At IPL we get:
IGGN307I sysr1,SYS1.PARMLIB.&SYSR1,DATA SET NOT FOUND ON VOLUME
IEA345A SYS1.PARMLIB.&SYSR1 NOT USED (NOT CATALOGED) - PRESS ENTER TO
CONTINUE
Case 2:
-------
Tried to cheat, defined ALIAS:
DEFINE ALIAS( NAME(SYS1.PARMLIB.SYSR1) -
SYMBOLICRELATE(SYS1.PARMLIB.&SYSR1))
PARMLIB SYS1.PARMLIB.SYSR1
At IPL we get:
IGGN307I sysr1,SYS1.PARMLIB.SYSR1,DATA SET NOT FOUND ON VOLUME
IEA345A SYS1.PARMLIB.SYSR1 NOT USED (NOT CATALOGED) - PRESS ENTER TO
CONTINUE
Needless to say, I am disappointed...
----------------------------------------------------------------------