Mark,

I doubt it has anything to do with the one byte ids. Here's what the
message book says:

FAILED BY MVS                                                    
                                                                 
          The MVS console command authority was insufficient for 
          this command.  Either:                                 
                                                                 
          t   no security product was active for this function,  
              or                                                 
                                                                 
          t   a security product was active for this function,   
              but it could not determine whether the command     
              should be allowed or failed.  



Alan.

                     
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Mark Jacobs

We have a vendor product, no longer under support, that issues operator 
commands when it starts up. When we have a zOS 1.8 system in the sysplex

the start commands fail with this message;

IEE345I START AUTHORITY INVALID, FAILED BY MVS

When the zOS 1.8 system is removed from the sysplex the start command is

successful. The issuing system is zOS 1.7.

I know that these commands are being issued with a one-byte console id 
since they show up in the DISPLAY OPDATA, TRACKING report.

Is there anything that I can do to get it to work or are we SOL.

----------------------------------------------------------------------