I am having various abends (S0c1, S0c4) with modules accessed through a
linklisted library.  The library itself appears to be fine.  If I
steplib to the library instead of accessing it through the linklist, my
job runs without issue.  I have recycled both LLA and VLF and still have
the same problem.

Any clues where else I can look?

My next step is going to be to remove the offending library from
linklist and re-add it.  If I still fail I will be removing it and
adding a different library which contains the same modules.

Thanks for any help.
Debbie Mitchell

</snip>

Debbie,

I remember (I am old and has been awhile), but IIRC there is a limit to
the number of extents a linklist can go. Flaky things start happening
when this does. You may want to check libraries with multiple extents. I
would especially concentrate on ones that recently had members added. We
try to not allocate secondary extents for linklisted datasets, but you
know how that goes.

Fletch

----------------------------------------------------------------------