On Tue, 14 Aug 2007 12:53:07 -0500, Debbie Mitchell
<[EMAIL PROTECTED]> wrote:

>I am having various abends (S0c1, S0c4) with modules accessed through a
>linklisted library.  The library itself appears to be fine.  If I steplib to
>the library instead of accessing it through the linklist, my job runs
>without issue.  I have recycled both LLA and VLF and still have the same
>problem.
>
>Any clues where else I can look?
>
>My next step is going to be to remove the offending library from linklist
>and re-add it.  If I still fail I will be removing it and adding a different
>library which contains the same modules.
>

Is the library a PDSE by any chance?  

--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[EMAIL PROTECTED]
z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/
Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html