Richbourg, Claude wrote: > Here is a listing of the syslib concat done on the 1.9 system. > > //SYSLIB DD DISP=SHR,DSN=SYS1.MACLIB > // DD DISP=SHR,DSN=SYS1.MODGEN > // DD DISP=SHR,DSN=CEE.SCEEMAC > // DD DISP=SHR,DSN=SYS1.SHASMAC > // DD DISP=SHR,DSN=TCPIP.SEZANMAC > // DD DISP=SHR,DSN=TCPIP.SEZACMAC > // DD DISP=SHR,DSN=JSYS.SHOW716.MACLIB > > Regards, > Claude >
The dataset names look fine but did the job actually execute on a zOS 1.9 system so it can allocate the correct levels of each dataset. > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On > Behalf Of Mark Jacobs > Sent: Friday, April 11, 2008 9:39 AM > To: [email protected] > Subject: Re: SHOWZOS output. > > Richbourg, Claude wrote: > >> Good morning all, >> >> This has been installed on our sandbox lpar running z/OS 1.9. >> After wrestling with it to get it working, I have run up against a >> > wall. > >> Would any of you who know this CBT utility take a gander at what is >> going on? >> I looked up the error code, but do not know what to change, or if I >> missed something. Please feel free to contact me off list if needed. >> Output follows and the job get zero return codes, but? >> >> >> IEA995I SYMPTOM DUMP OUTPUT 043 >> SYSTEM COMPLETION CODE=0C6 REASON CODE=00000006 >> TIME=09.25.28 SEQ=00253 CPU=0000 ASID=0031 >> PSW AT TIME OF ERROR 078D0000 93508A09 ILC 2 INTC 06 >> ACTIVE LOAD MODULE ADDRESS=13500B50 OFFSET=00007EB9 >> NAME=SHOWZOS >> DATA AT PSW 13508A03 - C5E25D00 000000C0 E50000A5 >> GR 0: 00000000_00000000 1: 00000000_000000B4 >> 2: 00000000_00001228 3: 00000000_00FE2710 >> 4: 00000000_13560AF0 5: 00000000_14CF501E >> 6: 00000000_00000000 7: 00000000_00000000 >> 8: 00000000_00FD8DD0 9: 00000000_008FF050 >> A: 00000000_13560ACD B: 00000000_008FF358 >> C: 00000000_1351E780 D: 00000000_00007008 >> E: 00000000_13508A06 F: 00000010_00000008 >> END OF SYMPTOM DUMP >> >> >> Regards, >> Claude Richbourg >> Florida Department of Corrections >> z/OS Systems Programmer >> 850-921-1383 >> >> >> >> > > Did you reassemble it using the zOS 1.9 maclibs? > > -- Mark Jacobs Time Customer Service Tampa, FL ---- We have a special climate-controlled room that keeps the worms at a low enough temerature so that they remain dormant. If the temperature varies by more than +-0.73K, the worms either freeze to death, or eat throught the CrTiAl alloy of the airlock doors. Dicey. -Branko Cibej <[EMAIL PROTECTED]>, concerning the can of worms ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html