On Thu, 15 May 2008 09:50:02 -0700, Skip Robinson <[EMAIL PROTECTED]>
wrote:

>If there is a driving system at the DR site, you use it to create the DR
>policy and store it in your own CFRM data set by volser before your first
>IPL. COUPLExx needs only the policy name. We got creative and decided to
>call ours POLICYDR, which is permanently coded in CFRMPOL in production.
>

Ok... got ya now.   Yes, that could easily be done from a floor system
or a RESCUE system that is IPLed first.  

Mark
--