On Thu, 15 May 2008 09:50:02 -0700, Skip Robinson <[EMAIL PROTECTED]> wrote:
>If there is a driving system at the DR site, you use it to create the DR >policy and store it in your own CFRM data set by volser before your first >IPL. COUPLExx needs only the policy name. We got creative and decided to >call ours POLICYDR, which is permanently coded in CFRMPOL in production. > Ok... got ya now. Yes, that could easily be done from a floor system or a RESCUE system that is IPLed first. Mark -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group - ZFUS G-ITO mailto:[EMAIL PROTECTED] z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html