Gary,
 
Issue a hsend q setsys   and see if you get the following:
 
MAXRECALLTASKS=05, RECALL=ANYSTORAGEVOLUME(LIKE), MAXEXTENTS=06,
(CONT.) CONVERSION=NO, VOLCOUNT=ANY, TAPERECALLLIMITS(TASK=00015
(CONT.) TAPE=00020)                                             
 
Volcount=any is what you are looking for. Now does the file being recalled have 
a Dataclass which allows multiple volumes? You may have to alter the catalog 
entry to a dataclass with a volcount greater than 1.

________________________________

From: Gary Green [mailto:[EMAIL PROTECTED]
Sent: Tue 5/20/2008 3:55 PM
To: [email protected]
Subject: DFHSM Abend



Wouild someone be able to help me save a bunch of research time with this 
problem.

We have a user that is attempting to recall a migrated dataset (standard JCL 
PDS).  However, DFHSM is getting an abend E37-04 during the recall process.  If 
this were a  recover I would allocate a new dataset, with appropriate 
attributes, and then ask HSM to replace the existing one.  However, the only 
options with a recall are volume, unit, wait, etc...  I tried it myself, even 
sendig the recalled ds to other volumes, all to no avail.

I do not recall getting anything like this for more than 10 years and I forgot 
the work-around.

Thanks for anything anyone can contribute.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO