That's not going to do much good, he said it was a PDS.

>>> "O'Brien, David W. (NIH/CIT) [C]" <[EMAIL PROTECTED]> 5/20/2008 4:13 PM >>>
Gary,

Issue a hsend q setsys   and see if you get the following:

MAXRECALLTASKS=05, RECALL=ANYSTORAGEVOLUME(LIKE), MAXEXTENTS=06,
(CONT.) CONVERSION=NO, VOLCOUNT=ANY, TAPERECALLLIMITS(TASK=00015
(CONT.) TAPE=00020)                                             

Volcount=any is what you are looking for. Now does the file being recalled have 
a Dataclass which allows multiple volumes? You may have to alter the catalog 
entry to a dataclass with a volcount greater than 1.

________________________________

From: Gary Green [mailto:[EMAIL PROTECTED] 
Sent: Tue 5/20/2008 3:55 PM
To: [email protected] 
Subject: DFHSM Abend



Wouild someone be able to help me save a bunch of research time with this 
problem.

We have a user that is attempting to recall a migrated dataset (standard JCL 
PDS).  However, DFHSM is getting an abend E37-04 during the recall process.  If 
this were a  recover I would allocate a new dataset, with appropriate 
attributes, and then ask HSM to replace the existing one.  However, the only 
options with a recall are volume, unit, wait, etc...  I tried it myself, even 
sendig the recalled ds to other volumes, all to no avail.

I do not recall getting anything like this for more than 10 years and I forgot 
the work-around.

Thanks for anything anyone can contribute.



Note that my email domain has changed from jo-annstores.com to joann.com.  
Please update your address book and other records to reflect this change.

CONFIDENTIALITY/EMAIL NOTICE: The material in this transmission contains 
confidential and privileged information intended only for the addressee.  If 
you are not the intended recipient, please be advised that you have received 
this material in error and that any forwarding, copying, printing, 
distribution, use or disclosure of the material is strictly prohibited.  If you 
have received this material in error, please (i) do not read it, (ii) reply to 
the sender that you received the message in error, and (iii) erase or destroy 
the material. Emails are not secure and can be intercepted, amended, lost or 
destroyed, or contain viruses. You are deemed to have accepted these risks if 
you communicate with us by email. Thank you.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to