Hi
Thank you., this was I have searched for ( I tried SYSUT3 , WORK etc )
If I can ask you about the possbility to PIPE (via USS or without) the
SYSUT1 and /or SYSUT2 ?
Robert Wright wrote:
Miklos Szigetvari wrote:
Try to TERSE a 3 Gbyte input file, and got IKJ56245I ," dynalloc
error, not enough space on volume " message,
Can I control this ?
See OA22765, an APAR closed as FIN because there currently is a
circumvention.
"AMATERSE currently uses ddname TMPSPACE as an intermediate and
asks whether that file has been preallocated. Supplying that
ddname allocated to a large data set can circumvent the
problem."
Bob Wright - MVS Service Aids
----------------------------------------------------------------------