Most errors that I have seen on virtual tape that would make sense only
on a physical tape were due to the VTS not being able to restage the
virtual volume back to the TVC (e.g. stacked volume stuck in drive) 

-----Original Message-----
Lizette Koehler

I have a production job down due to an S413 abend on a VTS (virtual)
tape data set.

I was wondering if this is a hardware problem or if there is something I
can do to "fix" the tape.  I have no additional error messages other
than the EQC.

Can a back end copy be used to recover the dataset?

IEF233A M 0B2B,502691,,LK41591C,COPYIT1,REV.A50776.G0024V00

IEF233A M 0B4D,PRIVAT,SL,LK41591C,COPYIT1,TSO.LK41591.RECOVR.TEST.TAPE

IOS000I 0B2B,12,EQC,07,0E00,,**,,LK41591C  455

 10480035000000206011(B310000102005115)0000(500007FF)CE3F209B27640B00

IEC512I I/O ERR 0B2B,502691,,LK41591C,COPYIT1,REV.A50776.G0024V00

IEC502E R 0B2B,,LK41591C,COPYIT1

TMS014  IEC502E R 0B2B,,LK41591C,COPYIT1

IEC145I
413-08,IFG0194K,LK41591C,COPYIT1,SYSUT1,0B2B,,REV.A50776.G0024V00    
IEA995I SYMPTOM DUMP OUTPUT  460

SYSTEM COMPLETION CODE=413  REASON CODE=00000008

 TIME=16.09.50  SEQ=02206  CPU=0000  ASID=008E

 PSW AT TIME OF ERROR  475C1000   80E729FE  ILC 2  INTC 0D

   NO ACTIVE MODULE FOUND

   NAME=UNKNOWN

   DATA AT PSW  00E729F8 - 41003B7A  0A0D41F0  38BE56F0

   GR 0: 00E72CC4   1: A4413000

      2: 00009820   3: 00E7214A

      4: 009CE410   5: 009CE7A4

      6: 009CE74C   7: 009CE7A4

      8: 009CE76C   9: 009CF680

      A: 009CF691   B: 00E74B04

      C: 80E74BE4   D: 009CE6D0

      E: 80E72282   F: 00000008                                
 END OF SYMPTOM DUMP                                           

Lizette

-

----------------------------------------------------------------------