Hal Merritt wrote:
We are looking to deploy a number of 'information only' consoles using
PC's and suitable TN3270 client software and the ICC. Of course, PC's
fail and just disappear. With full function consoles on a 2074 or Visara
controller, this can cause console buffer shortages.
Is this a potential issue with 'info only' consoles on ICC?

I think console restructure is supposed to help with this, but I don't
know if it completely eliminates it (maybe one of the IBM folks can
say).

Have you considered using SNA (SMCS) consoles? If they disconnect the
console is logged off. Of course if the TN3270 sessions hangs you
might be back to your original question.

--
Richard

----------------------------------------------------------------------