Eric Bielefeld wrote: > I finally figured out the answer to why I wasn't getting > any messages out at IPL time for my newly built 1.9 system. > Thanks to all who replied. The one suggestion that made > the biggest difference was to shut off the console and use > the hardware console. After I issued a D R,L command from > the hardware console, it showed the Enter JES2 parameters > message. I replied, and JES2 came up. I'm not sure quite > why I never saw that message before, but doing a D R,L from > the hardware console worked.
Next time, try D R,L,CN=(ALL) This will show requests queued to any console, not just the one you issue it from. Richard ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html