Eric Bielefeld wrote:
> I finally figured out the answer to why I wasn't getting
> any messages out at IPL time for my newly built 1.9 system.
> Thanks to all who replied.  The one suggestion that made
> the biggest difference was to shut off the console and use
> the hardware console.  After I issued a D R,L command from
> the hardware console, it showed the Enter JES2 parameters
> message.  I replied, and JES2 came up.  I'm not sure quite
> why I never saw that message before, but doing a D R,L from
> the hardware console worked.

Next time, try

D R,L,CN=(ALL)

This will show requests queued to any console, not just the
one you issue it from.

Richard

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html