IBM Mainframe Discussion List <[email protected]> wrote on 04/29/2009 08:23:25 AM:
> Another oddity. I tried the force and it said it was cancelable. So I > issued the CANCEL command and got the following: > > SYSTEM COMPLETION CODE=30D > TIME=08.12.41 SEQ=02209 CPU=0000 ASID=0001 > PSW AT TIME OF ERROR 070C4000 86936192 ILC 2 INTC 0D > NO ACTIVE MODULE FOUND > NAME=UNKNOWN > DATA AT PSW 0693618C - 1F001F11 05EF98EC D0649AEC > AR/GR 0: 00000000/00000000 1: 00000000/00000000 > 2: 00000000/7F1DAEB0 3: 00000000/05077B48 > 4: 00000000/00FD0D40 5: 00000002/008E6828 > 6: 00000002/7F1DAEB0 7: 00000000/05077B48 > 8: 00000000/7F5B2108 9: 00000000/7F5B2108 > A: 00000000/00000000 B: 00000000/06935B13 > C: 00000000/06934B14 D: 00000000/7F5B1E38 > E: 00000000/86936192 F: 00000000/00FFB34C > END OF SYMPTOM DUMP > IEF196I IEA995I SYMPTOM DUMP OUTPUT > IEF196I SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024 > IEF196I TIME=08.12.41 SEQ=02211 CPU=0000 ASID=0001 > IEF196I PSW AT TIME OF ERROR 070C5000 86996E7C ILC 2 INTC 0D > IEF196I NO ACTIVE MODULE FOUND > IEF196I NAME=UNKNOWN > IEF196I DATA AT PSW 06996E76 - 58F800AC 0A0D5830 D76C58B0 > IEF196I GR 0: 1F013647 1: 440F4000 > IEF196I 2: 00000000 3: 00000004 > IEF196I 4: 00000003 5: 7F5B1C78 > IEF196I 6: 00000024 7: 0507A4D0 > IEF196I 8: 7F5B1C78 9: 06996F38 > IEF196I A: 86996DDA B: 1F010000 > IEF196I C: 00FE3DA8 D: 7F5B1238 > IEF196I E: 86996E64 F: 00000024 > IEF196I END OF SYMPTOM DUMP > IEA995I SYMPTOM DUMP OUTPUT 734 > SYSTEM COMPLETION CODE=0F4 REASON CODE=00000024 > TIME=08.12.41 SEQ=02211 CPU=0000 ASID=0001 > PSW AT TIME OF ERROR 070C5000 86996E7C ILC 2 INTC 0D > NO ACTIVE MODULE FOUND > NAME=UNKNOWN > DATA AT PSW 06996E76 - 58F800AC 0A0D5830 D76C58B0 > GR 0: 1F013647 1: 440F4000 > 2: 00000000 3: 00000004 > 4: 00000003 5: 7F5B1C78 > 6: 00000024 7: 0507A4D0 > 8: 7F5B1C78 9: 06996F38 > A: 86996DDA B: 1F010000 > C: 00FE3DA8 D: 7F5B1238 > E: 86996E64 F: 00000024 > END OF SYMPTOM DUMP > IEF743I CICSRTT1 FORCED - CODE SA22 - IN ADDRESS SPACE 00C0 > > > Now I am totally confused. He started another region that is now > hanging. He is going to cancel with a dump and send it off to IBM. The 30D abend is due to RTM noticing that the memory termination TCB for the the terminating address space does not appear to be progressing, so it Abterms the task with a 30D. The 0F4 which follows suggests that the wait was in a data management resource manager, possibly something to do with PDSE processing. After terminating the data management resouce manager, memory termination proceeded and completed, so then you got the IEF743I CICSRTT1 FORCED - CODE SA22 - IN ADDRESS SPACE 00C0 Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html