COUPLE SYSPLEX(KFBP)
PCOUPLE(SYS1.XCF.KFBP.CDS01)
ACOUPLE(SYS1.XCF.KFBP.CDS02)
INTERVAL(85)
OPNOTIFY(87)
CLEANUP(15)
MAXMSG(2000)
RETRY(10)
DATA TYPE(WLM)
PCOUPLE(SYS1.WLM.KFBP.CDS01)
ACOUPLE(SYS1.WLM.KFBP.CDS02)
DATA TYPE(SFM)
PCOUPLE(SYS1.SFM.KFBP.CDS01)
ACOUPLE(SYS1.SFM.KFBP.CDS02)
DATA TYPE(LOGR)
PCOUPLE(SYS1.LOGR.KFBP.CDS01)
ACOUPLE(SYS1.LOGR.KFBP.CDS02)
CLASSDEF
CLASS(DEFAULT)
CLASSLEN(956)
CLASSDEF
CLASS(MEDIUM)
CLASSLEN(16316)
CLASSDEF
CLASS(LARGE)
What is EXSPAT?
Ken Klein
Sr. Systems Programmer
Kentucky Farm Bureau Insurance - Louisville
[email protected]
502-495-5000 x7011
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Barbara Nitz
Sent: Wednesday, July 08, 2009 8:29 AM
To: [email protected]
Subject: Re: Sysplex timeout problems.
I should have read the full post before replying.
What did you specify for OPNOTIFY, CLEANUP and INTERVAL in your
couplexx?
(We default all values.) What does your EXSPAT say? (It has an influence
- you need to read Init&Tuna and Setting up a Sysplex.)
The setting of these parms influences how long it takes until the
operator is notified (IXC102A) that a system is gone and needs to be
reset.
Barbara
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send
email to [email protected] with the message: GET IBM-MAIN INFO Search
the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html