Hi all,
I try to defined a FCTC but it always shows no logical path, I double
check the following setting but still don't know why?
1. The channel path is defined as long wave - correct
2. IODF setting is copied from first FCTC which is running currently. correct
3. The current ficon director is cascade with other ficon director, is
there any setting need to change from 6140 ficon director port ???
if the current IODF FCTC does not need cascade therefore the IODF
does not defined a domain ID
CU100 CNTLUNIT CUNUMBR=100,PATH=67,LINK=29,
CUADD=1,UNIT=FCTC,UNITADD=((00,5))
4. I try to block and unblock the port, doesn't work
IEE174I 20.49.18 DISPLAY M 071
CHPID 67: TYPE=1B, DESC=FICON SWITCHED, ONLINE
CHPID STATUS OUT OF SYNC, PHYSICAL=ONLINE, LOGICAL=OFFLINE
DEVICE STATUS FOR CHANNEL PATH 67
0 1 2 3 4 5 6 7 8 9 A B C D E F
010 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
011 +@ +@ +@ +@ . +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
012 +@ +@ +@ +@ . +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
013 +@ +@ +@ +@ . +@ +@ +@ +@ +@ . . . . . .
016 +@ +@ +@ +@ +@ . . . . . +@ +@ +@ +@ +@ +@
017 +@ +@ +@ +@ . +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
018 +@ +@ +@ +@ . +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@
019 +@ +@ +@ +@ . +@ +@ +@ +@ +@ . . . . . .
SWITCH DEVICE NUMBER = 00E2
DEFINED ENTRY SWITCH - LOGICAL SWITCH ID = 6E
ATTACHED ND = 006140.001.MCD.01.0000013G0709
PHYSICAL CHANNEL ID = 01C3
************************ SYMBOL EXPLANATIONS ************************
+ ONLINE @ PATH NOT VALIDATED - OFFLINE . DOES NOT EXIST
* PHYSICALLY ONLINE $ PATH NOT OPERATIONAL
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO