Mark,

You could try 
HSEND RECYCLE EXECUTE VOLUME(ML1078) FORCE

if that doesn't work

HSEND DELVOL ML1078 MIGRATION(PURGE
provided you are sure there's no valid data on the tape.
  
Thank You,
Dave O'Brien
NIH Contractor
________________________________________
From: Mark Pace [[email protected]]
Sent: Friday, June 29, 2012 9:43 AM
To: [email protected]
Subject: HSM tape

I'm trying to figure out why I have tapes that have no valid data, but
still show full.

ML1060   3590-1   ML2  0098302500 0000000000 000  *  EMPTY*   NO   *NONE*
*NONE*  001  ***   *NONE*  LIB001    TPSG
ML1078   3590-1   ML2  0003932100 0000000000 000   * FULL      *NO
*NONE*  *NONE*  001  ***   *NONE*  LIB001    TPSG


If I run RECYCLE ML2 EXECUTE PERCENTVALID(0)   it will show
ARC0830I RECYCLE COMMAND PROCESSING STARTING
ARC1007I COMMAND REQUEST 00000578 SENT TO DFSMSHSM
***

ARC0831I RECYCLE COMMAND PROCESSING ENDING
***


But I run another TTOC and the volume that was FULL still shows FULL.
Is there another way to force HSM to mark this volume as empty?


--