On Mon, 18 Feb 2013 11:32:46 -0800, retired mainframer 
<[email protected]> wrote:

>It is also possible for the RACF resource owner of a dataset (specified in
>the RESOWNER field of the DFP operand on the ADDSD command) to have a
>default data class (specified in the DATACLASS field of the DFP operand of
>the ADDUSER/ADDGROUP command).  SMS will use this value if ACSDEFAULTS is
>set to YES in the PARMLIB member IGDSMSxx.

There's one aspect of the processing you missed, as "specified in the RESOWNER 
field of the DFP operand on the ADDSD command" neglects the default processing. 
If there's no DFP segment in the relevant DATASET profile, or it doesn't 
specify a RESOWNER, then RACF will assign the HLQ of the DATASET profile (if 
it's a user ID or group name) as the RESOWNER.

-- 
Walt

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to