Matthew,

Each of those will ensure the output data set is extended format. That is not 
the issue. 
The issue is what program do I use to copy the data when LRECL=X.

Lennie Dymoke-Bradshaw

-----Original Message-----
From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On Behalf Of 
Matthew Stitt
Sent: 06 August 2020 20:56
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: Copy DSNTYPE=BASIC to DSNTYPE=EXTREQ with LRECL=X

My first thought is to use DSNTYPE on the output DD statement.  Second thought 
is to set up SMS DATACLAS and/or routine to make the output dataset EXTREQ.

Matthew

On Thu, 6 Aug 2020 17:20:12 +0000, Dymoke-Bradshaw, Lennie 
<lennie_dymokebradshaw...@bmc.com> wrote:

>Greetings,
>
>My requirement is in the title here.
>
>I want to copy data sets which have a DSNTYPE of BASIC to data sets with a 
>DSNTYPE of EXTREQ (i.e. extended format). However these data sets have LRECL=X 
>(i.e. LRECL larger than 32760).
>
>IDCAMS REPRO will not copy LRECL=X data sets.
>IEBGENER will copy LRECL=X but not if the attributes are different (as in this 
>case).
>
>I need a solution which works at access method level, so no solution using 
>DFSMSdss is acceptable.
>Anyone have any ideas?
>
>Lennie Dymoke-Bradshaw
>Consultant working on contract for BMC Mainframe Services by RSM 
>Partners 'Dance like no one is watching. Encrypt like everyone is.'

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to