On Fri, 16 Oct 2020 18:03:52 -0400, Joseph Reichman wrote:

You don't need to see the message to find out which text unit, if you are in 
TEST.
When 035C is returned in S99ERROR, the related S99TUKEY key is returned in 
S99INFO, immediately following S99ERROR.

Bll

>
>I am dynamically allocating a new file which has 14 test units. I am getting
>a 035C meaning one them is erroneous the doc says that message   IKJ56231I
>points me to the right text unit
>
>I am running this under TEST. I allocated SYSOUT to the terminal DA(*). I
>didn't see the message was wondering what file to allocate to DA(*) to see
>the message
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to