These are solution files that the vendor sends to us, so we have no control of what to do. They tell us that the target is a PDS or PDSE, but I was just looking for a backup method to try and ensure that what they say matches the file. As I'm sure you know, if they unloaded a PDS file with load modules, you can't take the unloaded file and then try to load it into a PDSE. Likewise, if a PDSE with program objects was unloaded, you can't load it into a standard PDS.
Billy

John Abell wrote on 7/29/2021 15:47:
Why not have them use TSO XMIT files like we do?

John T. Abell   
Tel:            800-295-7608    Option 4
President
International:  1-416-593-5578  Option 4
E-mail:  [email protected]
Fax:            800-295-7609

International:  1-416-593-5579


International Software Products
www.ispinfo.com
                                                                                
                
This email may contain confidential and privileged material for the sole use of 
the intended recipient(s). Any review, use, retention, distribution or 
disclosure by others is strictly prohibited. If you are not the intended
recipient (or authorized to receive on behalf of the named recipient), please 
contact the sender by reply email and delete all copies of this message. 
Also,email is susceptible to data corruption, interception,
tampering, unauthorized amendment and viruses. We only send and receive emails 
on the basis that we are not liable for any such corruption, interception, 
tampering, amendment or viruses or any consequence thereof.
        


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Billy Ashton
Sent: Thursday, July 29, 2021 2:37 PM
To: [email protected]
Subject: Identifying PDS/E or PDS in IEBCOPY Unload

Hey everyone, here is an odd question for y'all.
Is there any way I can tell from an IEBCOPY unload file (that I received from a 
vendor) whether it is an unload of a PDS or an unload of a PDS/E?
Since IEBCOPY is pretty particular about only loading full libraries back to 
the same source type, I was hoping I could look at byte 42 or something like 
that to know that I need to load this to a PDS/E.

Anybody have any hope for me here? (I know I can ask the vendor, but I wanted 
to confirm programmatically if possible).
Billy

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to