On Thu, Mar 21, 2013 at 10:23 AM, IP <[email protected]> wrote:
<deleted>
> Check: XCF_SIG_STR_SIZE
> Comment: This one just a raised a wonder in my head. It's not showing
> an exception rather a few warnings in the text of the check - that our
> signaling structures can't support the configuration specified with
> MAXSYSTEM. This is beacuse the sysplex where this occurs was big once,
> but now it's just a few LPARs. How could one reduce the MAXSYSTEM
> value while preserving other data in the CDSs? If I format a new CDS
> with a smaller MAXSYSTEM number, it won't play nice with the existing
> ones.
<deleted>

Per Barbara Nitz, create new, empty Coupling datasets.  Shut down all
LPARS and use the new dataset when the first system comes up.  She has
a user requirement for a command to purge systems from the coupling
datasets.
-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to