On Sun, 7 Apr 2013 11:44:43 -0700, Skip Robinson wrote:

>++MACUPD and ++SRCUPD depend entirely on FB sequence numbers. Without
>sequence numbers, every macro or source 'update' would have to be
>delivered as a complete replacement. For better or worse.
>
>I don't believe that VB sequence numbers have the same requirement because
>few (if any?) SMPE elements are delivered in VB format. At least not with
>sequence numbers.
> 
VB, HFS, inline load modules are delivered in an undocumented
format created by the GIMDTS utility.  SMP/E supplies the GIMDTS
utility to end users (mostly of use to ISVs), but does not supply
the un-GIMDTS utility.  And GIMDTS fails if RECFM=FB,LRECL=80
and no record contains "++" in columns 1-2.  So you can use
GIMDTS to encapsulate SMP/E MCS but not JCL.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN