Do you have BLOCKTOKENSIZE=LARGE  on the DCBE? Do you issue a CHECK before the 
NOTE?

If you want, take this offline to my Radus e-mail address.

Unfortunately to to IBM's OCO (יש"ו) policy, the logic manuals are not longer 
available; I'd stay away from using fields like DCBFDAD. TRKCALC doesn't really 
help.


--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3

________________________________________
From: IBM Mainframe Discussion List [[email protected]] on behalf of 
Joseph Reichman [[email protected]]
Sent: Friday, March 24, 2023 2:45 PM
To: [email protected]
Subject: Re: NOTE POINT and  DCBFDAD

At the point all I can say its a 3390

the DCBFDAD is being updated the NOTE macro keeps on returning 1
I added blksize to the DCBE and CAPACITYMODE=XCAP


Would you suggest I use devtyp and tracalc to get information to re-position 
the file using DCBFDAD

> On Mar 24, 2023, at 12:59 PM, Seymour J Metz <[email protected]> wrote:
>
> Check whether you have the right DCBE, etc., for a large volume. I would not 
> recommend messing with DCBFDAD.
>
> ________________________________________
> From: IBM Mainframe Discussion List <[email protected]> on behalf of 
> Joseph Reichman <[email protected]>
> Sent: Friday, March 24, 2023 11:39 AM
> To: [email protected]
> Subject: NOTE POINT and  DCBFDAD
>
> Hi
>
>
>
> For all those that asked why I was BSAM well. The data was not in the order
> I wanted.
>
>
>
> My Plan was to find what I want and than move it to a dataspce
>
>
>
> When I found what I wanted I would mark  it with a NOTE (I did have
> MACRF=RP) however NOTE always returned in R1 X'00000100' no matter where I
> stopped and when I used  POINT and did another READ it pointed me to the
> first record
>
>
>
> I am wondering since the POINT (for my BSAM VB) needs a TTR can I convert
> DCBFDAD to that the comment in DCB says "FULL DISK ADDRESS IN THE FORM OF
> MBBCCHHR"  can I some how get this as input to the Point
>
>
>
> I would assume HH is the same as track. I guess I would need to know what
> type of device I am using as that would tell me how many tracks per cylinder
>
>
>
> Thanks
>
>
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to