After adding BLOCKTOKENSIZE=SMALL to the DCBE 

The return from the note worked 
 Thank you 

> On Mar 25, 2023, at 3:04 PM, Binyamin Dissen <[email protected]> 
> wrote:
> 
> Before using a nuke to kill an ant, I would suggest verifying that the NOTE 
> is
> being issued when you expect it to be issued and that the position is what you
> expect.  That you issued CHECK.
> 
> Also, what device is the file on?
> 
> On Fri, 24 Mar 2023 11:39:09 -0400 Joseph Reichman <[email protected]>
> wrote:
> 
> :>For all those that asked why I was BSAM well. The data was not in the order
> :>I wanted. 
>> 
> :>My Plan was to find what I want and than move it to a dataspce
> 
> :>When I found what I wanted I would mark  it with a NOTE (I did have
> :>MACRF=RP) however NOTE always returned in R1 X'00000100' no matter where I
> :>stopped and when I used  POINT and did another READ it pointed me to the
> :>first record
> 
> :>I am wondering since the POINT (for my BSAM VB) needs a TTR can I convert
> :>DCBFDAD to that the comment in DCB says "FULL DISK ADDRESS IN THE FORM OF
> :>MBBCCHHR"  can I some how get this as input to the Point
> 
> :>I would assume HH is the same as track. I guess I would need to know what
> :>type of device I am using as that would tell me how many tracks per cylinder
> 
> --
> Binyamin Dissen <[email protected]>
> http://www.dissensoftware.com
> 
> Director, Dissen Software, Bar & Grill - Israel
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to