Tom Marchant asked:
>Are you trying to connect to the hardcopy SYSLOG device, if one id defined to 
>z/OS?

Um. Maybe? I'm trying to see things like
IEE389I MVS COMMAND PROCESSING AVAILABLE
so I know to send 
VINPUT VMSG V CN(*),ACT

>Or do you want to connect as a console terminal?
>Or do you want to see what would go to the console on the HMC?
>Or something else?
Does the previous response answer these? I dunno!

>What do you get if you issue D C from an operator console on MVS?
RESPONSE=S0W1
CNZ4100I 16.57.52 CONSOLE DISPLAY 662
CONSOLES MATCHING COMMAND: D C
MSG:CURR=0    LIM=1500 RPLY:CURR=0    LIM=99    SYS=S0W1     PFK=NONE
HARDCOPY  LOG=(SYSLOG)          CMDLEVEL=CMDS
       ROUT=(ALL)
S0W103E1  TYPE=MCS      STATUS=ACT-S0W1
           DEFINED=(*ALL)
           MATCHED=(*ALL)
    ATTRIBUTES ON S0W1
       AUTH=(MASTER)    CMDSYS=*            NBUF=0        SUPSBY=N
       DEV=03E1         LOGON=OPTIONAL      USERID=N/A      TIMEOUT=N/A
       MFORM=(T,J)      AREA=(Z)            PFKTAB=*DEFAULT
       USE=FC  DEL=RD   RTME=1    RNUM=19   SEG=19    CON=N
       LEVEL=(ALL)
       MONITOR=(NONE)                       INTIDS=N  UNKNIDS=N
       ROUT=(ALL)
       MSCOPE=(*ALL)

As you can tell, I know just about enough to be dangerous. But this is a dev 
system, nobody on it but us chickens.

 

And Steve Thompson suggested asking on IBMVM; I can do that, sure-I thought 
this would be more up MVSers' alley, but what do I know? Doesn't hurt to try, 
will do!


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN