UNIT is defined in the I/O gen and is customized by each site.  3390,
SYSDA, etc may or may not be present.

On Wed, Mar 20, 2024 at 1:57 AM ITschak Mugzach
<[email protected]> wrote:
>
> I have a program in Rexx that allocates a dataset using dsname and volume
> serial (1) . it works well in my shop but requires a unit type (2) in
> another shop. Actually the error is msg "IKJ56241I SPECIFIED UNIT IS
> UNDEFINED".
> Why does 1 work here and fails in another shop?
>
>    1. ALLOC F(XXX) DA('dsname') VOLUME(volser)
>    2. ALLOC F(XXX) DA('dsname') VOLUME(volser) UNIT(390)
>
> ITschak
>
> ITschak Mugzach
> *|** IronSphere Platform* *|* *Information Security Continuous Monitoring
> for z/OS, x/Linux & IBM I **| z/VM coming soon  *
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN



-- 
Mike A Schwab, Springfield IL USA
Where do Forest Rangers go to get away from it all?

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to