I think it is the data in the tso segment.

*| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere
Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux
and IBM I **|  *

*|* *Email**: i_mugz...@securiteam.co.il **|* *Mob**: +972 522 986404 **|*
*Skype**: ItschakMugzach **|* *Web**: www.Securiteam.co.il  **|*





On Wed, Mar 20, 2024 at 4:06 PM Michael Babcock <
000005ad4e2d7232-dmarc-requ...@listserv.ua.edu> wrote:

> SMS versus non-SMS?   Esoterics?
>
> On Wed, Mar 20, 2024 at 1:57 AM ITschak Mugzach <
> 000005a7ced721d8-dmarc-requ...@listserv.ua.edu> wrote:
>
> > I have a program in Rexx that allocates a dataset using dsname and volume
> > serial (1) . it works well in my shop but requires a unit type (2) in
> > another shop. Actually the error is msg "IKJ56241I SPECIFIED UNIT IS
> > UNDEFINED".
> > Why does 1 work here and fails in another shop?
> >
> >    1. ALLOC F(XXX) DA('dsname') VOLUME(volser)
> >    2. ALLOC F(XXX) DA('dsname') VOLUME(volser) UNIT(390)
> >
> > ITschak
> >
> > ITschak Mugzach
> > *|** IronSphere Platform* *|* *Information Security Continuous Monitoring
> > for z/OS, x/Linux & IBM I **| z/VM coming soon  *
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
> >
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to